iPERL alerts
The following information describes the alarms, errors, and warnings for the iPERL meter.
Meter event name | RNI event name | Event description | Event trigger | Event source | Xylem recommended action |
---|---|---|---|---|---|
Backflow/Reverse Flow | Reverse Flow | Water is flowing in the pipe in reverse for 15 minutes. | Water is flowing in the pipe in reverse for 15 minutes. | Smart Meter | Investigate. |
Config Error and Historical Config Error* | Configuration Error | Configuration file has been set to the defaults. | Set when no valid configuration is found and firmware loads the defaults for configuration. | Smart Meter | Investigate, reconfigure meter in field, make plans to replace meter soon. |
Critical Hardware Warning | Critical Hardware Warning | Meter has detected that some peripheral hardware may be failing, but this does not affect core water metrology. | Detection of possible hardware failure. | Smart Meter | Investigate. |
Dead Battery | Dead Battery | Meter battery is dead or too low to accumulate flow data. | Battery capacity drops below functional threshold. | Smart Meter | Replace the meter. |
EMF Range and Historical EMF Range | EMF Range | Voltage between electrodes is too large to measure water flow. | Voltage between electrodes is too large to measure water flow. | Smart Meter | Replace the meter. |
Empty Pipe | Empty Pipe | No water is detected for one minute. | Metrology had detected an empty pipe if no water is detected for one minute. | Smart Meter | Investigate. |
Glide Slope and Historical Glide Slope | Glide Slope | Battery monitoring algorithm is detecting current consumption greater than expected. | Battery monitoring algorithm is detecting current consumption greater than expected. | Smart Meter | This alarm is informational. |
High Current | High Current | Meter may be consuming excessive power, possibly due to frequent bidirectional communications. | Meter estimates power consumption is over 4 times target budget. | Smart Meter | Investigate. |
High Current and Historical High Current | High Current | Set if the 15 minute power estimator power consumption is 4x more than expected. Early detection of high power consumption. | Set if 1 minute power estimator power consumption is 4x more than expected. Early detection of high power consumption or magnetic tamper. | Smart Meter | Investigate. |
High Temperature and Historical High Temperature | Register Over Temperature | Temperature exceeded the maximum temperature for rated components for one hour. | Temperature exceeded the maximum temperature for rated components for one hour. | Smart Meter | This alarm is informational. |
Leak | Continuous Flow | Metrology detects continuous forward flow of any rate for 24 hours or more. | Metrology detects continuous forward flow of any rate for 24 hours (or more) | Smart Meter | Investigate. |
Low Field and Historical Low Field | Low Field | Magnetic field has drifted outside of expected field range. Early detection of magnetic tamper. | Magnetic field has drifted outside of expected field range. Early detection of magnetic tamper. | Smart Meter | Informational. |
Magnetic Tamper | Magnetic Tamper | Meter could not regulate the magnetic field for 15 minutes. | Meter could not regulate the magnetic field for 15 minutes. | Smart Meter | Investigate. |
Meter Low Battery* | Low Metrology Battery Volts | This is an indication that end of the device's estimated life is nearing. There is less than six months of battery life left. | 1. Time in 'idle' mode 2. Time active (normal operation) 3. The calculated consumption amount. | Smart Meter | Make plans to replace meter soon. |
Metrology Communications Error | Internal Communication Error | Meter is unable to communicate with metrology core. | Meter is unable to communicate with metrology core. | Smart Meter | Return Material Authorization (RMA) to Sensus or replace the meter. |
Misc Metrology | The metrology data is potentially becoming unreliable due to high noise or excessive flow rate. | High noise: There is a potential degradation in meter accuracy caused by an applied external electric current on or in the water line that exceeds the threshold for at least 15 minutes. Excessive flow rate: This threshold is programmable after R1.1.xx. Prior to that release, the maximum allowable flow rate is 55 gpm, the maximum flow physically possible for a 3/4" ally meter. | Smart Meter | If this alarm is caused by high noise, it will clear when the noise drops below the programmed threshold, or if the meter enters empty pipe mode. | |
Non-Volatile Memory Error | Configuration Error | Data violation. The configuration file and calibration file do not match. | Data violation; the configuration file and calibration file do not match. | Smart Meter | Return Material Authorization (RMA) to Sensus. Sensus will troubleshoot, reconfigure or upgrade the firmware. |
Reboot | Meter Reboot | Meter has rebooted. | Meter has rebooted. | Smart Meter | Investigate excessive reboots. |
Severe Hardware Problem | Hardware Failure | The controller is not communicating with the metrology chip. No accumulation of water flow was collected. | Core metrology hardware failure or calibration data corruption. | Smart Meter | Return Material Authorization (RMA) to Sensus or replace the meter. |
SmartMeter Low Battery Volts and Historical Low Battery Volts* | Low Metrology Battery Volts | Meter's battery volts has dropped to 2.5V for at least one hour. | Meter's battery volts has dropped to 2.5V for at least one hour. | Smart Meter | The alarm will clear if the battery’s voltage goes above the threshold; no further action is required. If the low battery flag is continually detected this is an indicator that the unit needs to be replaced. |
SmartMeter TouchRead Failure and Historical TouchRead Failure | Touch Read Failure | Communications error detected on the Touchcouple interface by the meter. | Communications error detected on the Touchcouple interface by the meter. | Smart Meter | Investigate. |
Swapped Meter | Swapped Meter | Meter has been changed without properly configuring the SmartPoint module. | Meter has been changed without properly configuring the SmartPoint module. | Smart Meter | Investigate. |
Upgrade Mode | Upgrade Mode | The meter gets stuck in firmware upgrade mode. While in this mode no accumulation of water flow is collected. | Initiation of firmware upgrade. | Smart Meter | Water meter metrology can only be upgraded in the field or by Sensus. Use the tool to exit the upgrade mode. |