Cordonel alarms

The following describes the alarms, errors, and warnings for the Cordonel meter.

Alarms will display on the meter with the alarm flag lit, followed by "ALr" and the alarm code. Alarm codes will display for two seconds each every minute.

Table 1. Cordonel NA alerts
LCD code Meter event nameRNI event nameEvent descriptionEvent triggerEvent sourceXylem recommended action
bBeyond End of LifeBeyond End of LifeTriggers when the product has reached the end of the expected product life base on years.Triggers after 20 yrs from install or 21 yrs from date of manufacture.Smart MeterPlan scheduled maintenance.
FConfiguration ErrorConfiguration ErrorFactory Seal is not set.Configuration error alarm becomes active when factory seal is not set. Alarm is checked once an hour.Smart MeterInvestigate.
ECritical Hardware WarningCritical Hardware WarningThere may be an issue with peripheral meter hardware, though core metrology functions are not impacted.Meter fault is detected.Smart MeterInvestigate.
LCustomer LeakContinuous FlowTriggers when the flow rate through the meter meets or exceeds the configured value for the configured period of time.User configurable thresholds, defaults and permitted ranges based on meter size.Smart MeterInvestigate.
0 (zero)Empty PipeEmpty PipeTriggers when air is detected in the pipe and indicates there is no water in the flow tube.Triggers when air is detected in the pipe and indicates there is no water in the flow tube.Smart MeterInvestigate.
HHigh FlowHigh FlowTriggers when the flow rate though the meter meets or exceeds the set value for the set time. Could be caused by a broken pipe.User configurable thresholds, defaults and permitted ranges based on meter size.Smart MeterInvestigate.
1High Pressure AlarmHigh PressureTriggers when pressure rises above the set threshold.Triggers when pressure is above set threshold. The defaults are 200 PSIG, 13.8 bar, 1.38 MPa over 1 minute.Smart MeterInvestigate.
3High Temperature AlarmHigh TemperatureTriggers when the temperature rises above the set range.Triggers when temperature is above the set temperature. The defaults are 80F, 27C over a minute.Smart MeterInvestigate.
2Low Pressure AlarmLow PressureTriggers when pressure drops below the set threshold.Triggers when pressure falls below the set threshold. The defaults are 35 PSIG, 2.4 bar, 0.24 MPa over a minute duration.Smart MeterInvestigate.
bLow Primary Battery VoltsLow Metrology Battery VoltsTriggers when voltage supplied to the metrology is running low.Triggers when volts drops below 2.8V.Smart MeterPlan scheduled maintenance.
4Low Temperature AlarmLow TemperatureTriggers when the temperature drops below the set range.Triggers when temperature falls below the set temperature. The defaults are 35F, 2C over a minute.Smart MeterInvestigate.
bNear End of LifeNear End of LifeTriggers when the product is near the end of the expected product life based on years.Triggers after 19.5 yrs from install or 20.5 yrs from date of manufacture.Smart MeterPlan scheduled maintenance.
FRebootMeter RebootMeter has rebooted.Meter has rebooted.Smart MeterInvestigate.
rReverse FlowReverse FlowTriggers an alert when there is a consistent reverse flow for a specified period of time.User configurable thresholds, defaults and permitted ranges based on meter size.Smart MeterInvestigate.
FUpgrade ModeUpgrade ModeSet if the unit is in a mode that is updating the firmware.Triggered by receipt of a command to start Firmware Update.Smart MeterInvestigate.
tRegister removal tamper.An attempt to remove the register is detected.Investigate.
FFault. There may be an issue with the meter.Investigate.
EReplace Meter Event/RMA. The meter operation has been compromised.Investigate.